Przejdź do zawartości

New firmware release - 0454 - InBody270, 370S, 570 and 770

17 sierpnia 2026 przez
New firmware release - 0454 - InBody270, 370S, 570 and 770
Hanul Shin

Please note a major change when using custom URL such as with eGym integration https://inbodyeu.zohodesk.eu/portal/en/kb/articles/using-custom-url-unable-to-connect-to-the-server


Dear all,


A new digital firmware has been released. With this firmware, please make sure to use the latest Analog firmware. 


The changes : 


[UI and function modifications]

1. (Request 23-0644) Korean Pediatric Association 2017 Change in pediatric growth curve standard value and Ref in the results sheet. Mark  - The existing 1-year unit evaluation value for children was divided into 10 equal parts and evaluated at 0.1-year units, but the standard value at 0.1-year units was applied.  - Modified the growth curve to be displayed as *KCDC2007 or *KCDC2017 on the result sheet when selecting Korean Pediatric Association 2007 or Korean Pediatric Association 2017.

2. (Request 23-0284) LB WEB security function update  - LB WEB API 3.0 (TOKEN method) applied  - When logging in, the token value is downloaded from the server and modified to communicate only if the token value is valid for a certain period of time.  - Updated to existing API V2.

3. (Request 24-0005) Addition of InBody grip dynamometer linkage function  - Connected via Bluetooth, and when linked to the grip dynamometer, the grip strength test UI is performed after the InBody test is completed.  - "Sarcopenia item" and "Muscle strength item" were added to the right side of the result sheet. (For Korean, only the muscle strength item was added, and for other languages, only the sarcopenia item was added to the muscle strength item.)

4. (Request 23-0713) Change the existing minimum weight range of 5kg to 2kg.  - On the main screen, when you step on the footrest, the part that previously had to be recognized as 5kg or more to move to the weight measurement screen has been modified to move to the weight measurement screen when 2kg or more is recognized.

5. (Request 23-0777) Contact customer service center for subscription function -> Modify text by contacting user

6. (Request 23-0690) Addition of Bluetooth dongle recognition/classification function inside the device  - Bluetooth information is output when entering the QC Report in test mode.  - (BT: BT2): INBT200 available.  - (BT: BT4(5)): INBT400 or 500 available.

8. (Request 24-0007) Added the ability to synchronize LB120 with compatible equipment via Bluetooth (* Only INBT400 or INBT500 can be used - In case of INBT200, old UI appears)  - When entering the Bluetooth connection screen in the settings, LB120 is always checked, and if you set up additional connection with compatible devices on the right, you can use LB120 and compatible devices simultaneously.

9. (Request 24-0065) Apply to production department request  - Fixed an issue where the date format and unit part among the values automatically set after changing the language during production were not updated.  - Fixed issue with DAPC error output.


The firmware can be downloaded in their respective page on the Knowledge base : 


InBody270

InBody370S

InBody570

InBody770

InBody970/BWA2.0 - Sata2 removed from LNO31 and INO31